Details
The Drive Medical Med-Aire Alternating Pressure Mattress Overlay System is designed to be used in the prevention, treatment and management of Pressure Ulcers. The WHISPER QUIET", pump produces consistent air flow. Special vibration isolating features insure that the patient rests easily, without feeling the pumps vibrating action. LED indicators provide critical performance data and alert caregiver when pressure falls below 10mmHg (inner mattress pressure). Easy to replace individual bladders. Mattress has 20 air bladders, nine (9) with laser holes to achieve low air loss function, to increase patient comfort, keep the patient cool and speed recovery. Quick fill adapter and carry bag standard. Spring lined air tubes prevent kinks and disruption of air flow. CPR valves provide fast (20-Second) deflation. 8-Inch high air cells are constructed with Nylon/50% TPU for durability.
Additional Information
| Features |
- The product is designed to be used in theprevention, treatment and management ofPressure Ulcers
- The “WHISPER QUIET”, pump produces consistent air flow
- Special vibration isolating features insure that the patient rests easily, without feeling the pumps vibrating action
- LED indicators provide critical performance data and alert caregiver when pressure falls below 10mmHg (inner mattress pressure)
- Easy to replace individual bladders
- Mattress has 20 air bladders, nine (9) with laser holesto achieve low air loss function, to increase patient comfort,keep the patient cool and speed recovery
- Quick fill adapter and carry bag standard
- Spring lined air tubes prevent kinks and disruption of air flow
- CPR valves provide fast (20-Second) deflation
- 8-Inch high air cells are constructed with Nylon/50%TPU for durability
|
| Items Included |
|
| Specifications |
| Power: 120 VAC | Topper Material: Zippered and Quilted Urethane Coated Nylon Fabric (2-Way Stretch) is; water resistant, vapor permeable, machine washable and low sheer | | Frequency: 60 HZ | Base Material: Zippered Vinyl | Pressure Range: 30 mmHg to 80 mmHg (inner mattress pressure) | 4-Air cells at head section remain static to enhance pillow function | | Air volume: 8-LPM (Litres per Minute) | Dimensions: 36W x 80L x 8H | | Cycle Time: 10 Minutes | Maximum Support Capacity: 300 lbs. | | Functions: Static and Dynamic Features | Warranty: 18-Months Limited | | Power Cord Length: 14.76 Ft. | | | Pump Dimensions: 11 (W) x 8 (H) x 3.5 (D) | | | Maximum Current: 0.5 Amps | | | Warranty: 18 Months Limited | | |